TM-9-1200-215-34-P

AUTOMATIC FIRE CONTROL SYSTEM (AFCS)

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

FEBRUARY 1999

  TM-9-1200-215-34-P - Page 89 of 266

TM 9–1200–215–34&P
2–54
2–25.
ACU HANDLE MAINTENANCE INSTRUCTIONS
DESCRIPTION
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools:
Tool Kits, JTK–17LAL, TK–101/G, or TK–105/G
(items 34, 35, & 36, Appendix E)
Torque Wrench, 0–75 in.–lb (item 40, Appendix E)
Torque Wrench, 0–15 in.–lb (item 39, Appendix E)
Torque Wrench, 0–50 ft–lb (item 68, Appendix E)
#2 Crosstip Screwdriver Socket Wrench
(item 22, Appendix E)
Materials/Parts:
Lockwasher (item 1, Appendix F)
Screw, Machine (item 10, Appendix F)
Equipment Conditions:
Unenergized ACU is on workbench
Personnel Required:
One MOS 35Y
a.
REMOVAL
CAUTION
ESD SENSITIVE
The ACU contains ESD sensitive
components. Wear a protective
ESD wrist strap whenever handling
components. Failure to comply may
result in damage to equipment.
NOTE
When removing handle from the left
side of ACU, perform steps 1
through 10.
When removing handle
from the right side of ACU, perform
steps 1, 2, 11,
9, and 10.
Handle is supplied from vendor with
nuts and washers.
1.
Attach ESD grounding strap to wrist and
ground to ensure ESD protection.
2.
Remove top panel in accordance with
procedure outlined in paragraph 2–13.


Back to Top