TM 9-2350-260-20-1-2
FUEL-WATER SEPARATOR OPERATIONAL TESTS (2D ENGINE) (Sheet 7 of 11)
WARNING
Do not let upper (E) and lower (F) sensor probes come into direct contact with
each other.
Do not let upper (E) or lower (F) sensor probes come into contact with metal
container (G).
Hold insulated cables (J) attached to upper (E) and lower (F) sensor probes.
Do
not touch either probe.
8.
Hold tips of both upper (E) and lower (F) sensor
probes in water in metal container (G) until fluid
stops draining from solenoid drain valve drain tube
(H).
9.
If fluid does not stop draining from solenoid drain
valve drain tube (H) within 15-20 seconds from
starting, refer to troubleshooting procedures (page
4-256).
10.
If fluid does begin draining go to step 11 and then
to sequential drain test on next page.
11.
Remove upper (E) and lower (F) sensor probes
from metal container (G).
Go on to Sheet 8
TA148326
7-251