FUEL-WATER SEPARATOR OPERATIONAL TESTS (2D ENGINE) (Sheet 9 of 11)
WARNING
Do not let upper (E) and lower (F) sensor probes come into direct contact with
each other.
Do not let upper (E) or lower (F) sensor probes come into contact with metal
container (G).
Hold insulated cables (H) attached to upper (E) and lower (F) sensor probes.
Do
not touch either probe.
NOTE
Steps 8 thru 11 must be performed
within 15 seconds.
8.
Hold tip of lower () sensor probe in water in metal
container (G).
9.
Hold tip of upper (E) sensor probe in water in
metal container (G) and check if fluid starts
draining from solenoid drain valve drain tube (J).
10.
Remove tip of upper (E) sensor probe from water
in metal container (G) and check if fluid keeps
draining from solenoid drain valve drain tube (J).
Go on to Sheet 10