TM 9-2350-260-20-1-3
SHIFTING CONTROL GASKET REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
1.
Position new gasket (A) and spacer (B) over mounting holes.
2.
Using socket, install four new lockwashers (C) and screws (D).
3.
Install 2A powerplant (page 5-14) or 2D powerplant (page 5-40).
End of Task
TA146597