26. PLACE OUTPUT HOUSING (1) ON
TWO WOOD BLOCKS (ITEM 4)
SO THAT SPUR GEAR (2) IS
NOT TOUCHING WORKBENCH.
28. POSITION MEASURING PLATE (5)
ACROSS OUTPUT HOUSING
COLLAR (6).
a. Place plate (5) across output
housing collar (6).
b. Position plate (5) to cover half of
output carrier splined hole (7).
27. SEAT CONE AND ROLLERS (3)
IN HOUSING (1).
a. Using plastic faced hammer,
gently tap carrier assembly (4)
down until cone and rollers (3)
are fully seated.
29. OBTAIN DIMENSION B.
a. Using depth gage, measure
distance from top of plate (5) to
bottom of splined hole (7).
b. Record results as dimension B.
c. Remove plate.
4-300
Change 2
GO TO NEXT PAGE