TM-9-2815-205-34

ENGINE WITH CONTAINER; MODELS 5063-5299, 5063-5392, 5063-5393, 5063-5395, 5063-5398, 5063-539F, 5063-539L

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE

AUGUST 1992

  TM-9-2815-205-34 - Page 197 of 596

TM 9-2815-205-34
3-20. ROCKER ARM COVERS REPLACEMENT (MODELS 5063-5299 AND 5063-5398)
This task covers: a. Removal
b. Cleaning/Inspection
c. Installation
INITIAL SETUP
MODELS
MATERIALS/PARTS
5063-5299 5063-5398
2
Gaskets (App F, Item 71)
TOOLS AND SPECIAL TOOLS
EXPENDABLE/DURABLE SUPPLIES
Tool kit, general mechanics (App B, Item 107)
Cleaning solvent (App C, Item 9)
a. Removal
NOT E
Right and left rocker arm covers are identical except for oil filler hole and breather tube.
Use same procedure to remove both covers.
(1) Remove four screw and clamp assemblies (1), rocker arm cover (2), and gasket (3) from
cylinder head. Discard gasket.
(2) If necessary, disconnect clip (4) and remove oil filler cap assembly (5) from rocker arm cover
(2).
b. Cleaning/Inspection
Ž
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles
and gloves and use in a well-ventilated area. Avoid contact with skin, eyes, and
clothes. Do not breathe vapors. Do not use near open frame or excessive heat.
The flash point is 100-138°F (38-50°C). if you become dizzy while using cleaning
solvent, get fresh air immediately and seek medical aid. If contact with eyes is
made, wash with water and get medical aid immediately.
Compressed air used for cleaning purposes will not exceed 30 PSI. Use only
with effective chip guarding and personal protective equipment (goggles/shield,
gloves, etc.)
(1) Clean rocker arm covers with cleaning solvent and dry with compressed air.
(2) Inspect covers for cracks, dents, or other damage.
3-68
WARNING


Back to Top