TM 9-2815-210-34-2-2
FRAME 16
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame.
Keep a fire extinguisher nearby when
solvent is used.
Use only in well-ventilated places.
Failure to do this may result in injury to personnel and
damage to equipment.
NOTE
Gasket surface of cylinder head (1) was already checked
for nicks, scratches, and burrs. Do not try to fix gasket
surface in this frame.
1.
Check that cylinder head (1) has no small nicks, scratches or burrs. Fix
small nicks, scratches, or burrs with fine mill file or crocus cloth dipped in
dry cleaning solvent.
2.
Screw tap into all threaded holes in cylinder head (1) to clean threads.
IF CYLINDER HEAD (1) OR ANY PART OF CYLINDER HEAD WAS TAGGED FOR
MACHINING , GO TO FRAME 17.
IF CYLINDER HEAD (1) WAS NOT TAGGED FOR MACHINING, GO TO FRAME 21