TM 9-2815-210-34-2-2
FRAME 3
1.
2.
3.
4.
5.
Check that two pipe plugs (1), square head pipe plug (2), and two valve
plugs (3) are not cracked and do not have damaged threads. Check that
square head of square head pipe plug is not rounded. If pipe plugs,
square head pipe plug, or valve plugs are damaged, throw them away and
get new ones.
Check that 16 mounting screws (4) and long mounting bolt (5) do not have
stripped or damaged threads or rounded heads. Check that 16 mounting
washers (6) and mounting washer (7) are not cracked or broken. Throw
away damaged screws, bolt, and washers and get new ones.
Check that two springs (8) are not cracked or squeezed shut. If two springs
are cracked or squeezed shut, throw them away and get new ones.
WARNING
Dry cleaning solvent is flammable. D
O
not use near
an open flame.
Keep a fire extinguisher nearby when
solvent is used.
Use only in well-ventilated places.
Failure to do this may result in injury to personnel and
damage to equipment.
Check that two plungers (9) have no scratches or burrs. Fix small burrs and
scratches with crocus cloth dipped in dry cleaning solvent. Polish two
plungers with crocus cloth dipped in dry cleaning solvent even if they are not
scratched.
Check that two plungers (9) fit and move freely in bores in oil cooler and
filter housing (10).
If plungers bind in bores, throw away plungers and get
new ones.
If new plungers still bind in bores, get a new oil cooler and filter
housing.
GO TO FRAME 4
4-319