0052-17
Change 1
TB 9-3950-253-13&P
0052
HEMTT STOWAGE ASSEMBLY INSTALLATION – CONTINUED
NOTE
•
After relieving air pressure from system ensure relief valve is closed.
•
Perform steps 43 through 47 for HEMTT M1120.
•
Perform steps 48 through 51 for HEMTT M1120A4.
43. Release air pressure from system (TM 9-2320-326-14&P).
44. Remove quick disconnect air fitting (Figure 15, Item 1) from air tank fitting (Figure 15, Item 2).
45. Apply thread tape on pneumatic T-fitting (Figure 15, Item 3) and install pneumatic T-fitting on air tank fitting
(Figure 15, Item 2).
46. Apply thread tape on quick disconnect air fitting (Figure 15, Item 1) and install quick disconnect air fitting on
pneumatic T-fitting (Figure 15, Item 2).
47. Cut air hose (Figure 15, Item 4) to fit, and install on pneumatic fitting (Figure 15, Item 3).
Figure 15.
HEMTT M1120 Pneumatic Fitting and Hose Installation.
052
467-115
4
2
3
1
2
1