TB 9-3950-253-13&P
Change 1
0052-18
0052
HEMTT STOWAGE ASSEMBLY INSTALLATION – CONTINUED
48. Remove hose fitting (Figure 16, Item 3) from tank fitting (Figure 16, Item 4).
49. Apply thread tape on T-fitting (Figure 16, Item 5) and install T-fitting on tank fitting (Figure 16, Item 4).
50. Apply thread tape on hose fitting (Figure 16, Item 3) and install hose fitting on T-fitting (Figure 16, Item 5).
51. Cut air hose (Figure 16, Item 1) to fit and install on pneumatic fitting (Figure 16, Item 2).
Figure 16.
HEMTT M1120A4 Pneumatic Fitting and Hose Installation.
052
52. Move hook arm to stowed position (TM 9-2320-326-14&P).
NOTE
Rear edge of stowage assembly must be positioned 3 1/8 in. (80 mm) from front edge of
stowed hook arm. Measure distance on right and left sides of hook arm for accurate
placement of stowage assembly.
53. Adjust placement of stowage assembly (Figure 17, Item 1) on frame until distance between stowage assembly
and front edge of hook arm (Figure 17, Item 2) measures 3 1/8 in. (80 mm).