HEATSINK ASSEMBLY MAINTENANCE INSTRUCTIONS
DESCRIPTION
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools:
Tool Kit, JTK–17LAL, TK–101/G, or TK–105/G
(items 34, 35, & 36, Appendix E)
Torque Wrench, 0–15 in.–lb (item 39, Appendix E)
#2 Crosstip Screwdriver Socketwrench
(item 22, Appendix E)
Work Station Kit, Electronic (item 38, Appendix E)
Materials/Parts:
Sack, Shipping (ESD) (item 23, Appendix D)
Equipment Condition:
CCA removed; if not, remove CCA in accordance
with procedure in paragraph 5–15.
Personnel Required:
One MOS 35Y
a.
REMOVAL
CAUTION
ESD SENSITIVE
The VMS Modem contains ESD
sensitive components.
Wear a
protective ESD wrist strap whenever
handling components.
Failure to
comply may result in damage to
equipment.
1.
Attach ESD grounding strap to wrist and
ground to ensure ESD protection.
2.
Loosen connector screws (1) from receptacle
J3 (2) on heatsink assembly (3).
3.
Remove cable connector P3 (4) from
receptacle J3 (2).
4.
Remove sic screws (5) and six washers (6)
securing heatsink assembly (3) to housing (7).
5.
Lift heatsink assembly (3) from VMS Modem
housing (7) and place in ESD safe container.
Change 1
5
6
4
7
1
2
3