TM-9-1200-215-34-P

AUTOMATIC FIRE CONTROL SYSTEM (AFCS)

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

FEBRUARY 1999

  TM-9-1200-215-34-P - Page 145 of 266

TM 9–1200–215–34&P
5–7
5–13.
COVER MAINTENANCE INSTRUCTIONS
DESCRIPTION
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools:
Tool Kit, JTK–17LAL, TK–101/G, or TK–105/G
(items 34, 35, & 36, Appendix E)
Torque Wrench, 0–15 in.–lb (item 39, Appendix E)
#2 Crosstip Screwdriver Socketwrench (item 22,
Appendix E)
Work Station Kit, Electronic (item 38, Appendix E)
Equipment Condition:
Unenergized VMS Modem is on workbench
Personnel Required:
One MOS 35Y
a.
REMOVAL
CAUTION
ESD SENSITIVE
The VMS Modem contains ESD
sensitive components.
Wear a
protective ESD wrist strap whenever
handling components.
Failure to
comply may result in damage to
equipment.
1.
Attach ESD grounding strap to wrist and
ground to ensure ESD protection.
2.
Remove cover (1) by removing 12 screws (2)
and 12 flat washers (3).
Lift cover off housing.
CAUTION
The EMI shielding gasket is vital to
this piece of equipment and is easily
damaged.
Handle with care when
removing or replacing it.
Failure to
comply may result in damage to
equipment.
3.
Inspect EMI shielding gasket (4) in groove in
housing (5) for cuts, nicks, or signs of
stretching.
Discard EMI shielding gasket if
unserviceable.
1
2
3
4
5


Back to Top