Figure 5-113
Figure 5-115
Figure 5-114
Figure 5-116
Install two remaining diaphragm bolts and
washers. Tighten bolts to 17 to 20 pound-feet
torque. Remove one pitot tube guide bolt (A), and
install pitot tube bolt and washer (B) finger-tight.
Remove remaining guide bolt, and install other
pitot tube and washer. Tighten bolts to 2.5 to 4.5
pou rid-feet torque.
(Guide bolts are part of set
Install converter pump assembly (A), and make
certain that flats (B) on converter pump hub
engage flats in front oil pump drive gear.
Install pump seal (A), splined spacer (B), and snap
ring (C).
Install stator assembly (A) with roller race
counterbore down.