TM 9-2520-270-34
27. POSITION MEASURING PLATE (1)
ACROSS OUTPUT HOUSING
COLLAR (2).
a. Place plate (1) across output
housing collar (2).
b. Position plate (1) to cover half of
output carrier splined hole (3).
STEP 28 DIMENSION B 0.
INCH
STEP 23 DIMENSION A - 0.
INCH
STEP 29 DIMENSION C = 0.
INCH
29. OBTAIN DIMENSION C.
a. Subtract dimension A from
dimension B.
b. Record as dimension C.
28. OBTAIN DIMENSlON B.
a. Using depth gage, measure distance
from top of plate (1) to bottom of
splined hole (3).
b. Record results as dimension B.
c. Remove pIate (1).
30. SELECT NEW WASHER (4) FROM SHIM
SET.
a. Using micrometer caliper set measure
one washer (4) from shim set that is
0.006 to 0.013 inch (0.15 to 0.33 mm)
less than dimension C.
GO TO NEXT PAGE
Change 3
4-343