MWO-5-2350-262-35-2

ARMORED COMBAT EARTHMOVER (ACE), M9

MODIFICATION WORK ORDER

  MWO-5-2350-262-35-2 - Page 18 of 33

MWO 5-2350-262-35-2
2-13
NOTE
Step 5 below applies to Figure 2-15.
5.
Route and connect the opposite end of the MCU Power Lead (12491611-1) (2) to the power terminal (3) on
the top of the engine behind the alternator.
Use 5 or 6 Electrical Tie Straps (MS 3367-2-0) (1) to fasten the
MCU Power Lead (1) to the right outside of the driver’s compartment where required.
2
3
1
Figure 2-15.
MCU Power Lead Connection at Engine Terminal.
f.
Connecting the Coolant Umbilical assembly and Electrical Leads to the MCU:
NOTE
Steps 1 and 2 below apply to Figure 2-16.
1.
Adjust coolant umbilical (1) and MCU wiring harness power lead (2) so excess umbilical and power lead are
outside and behind the left rear of the driver’s compartment.
2.
Secure the positive electrical lead (3) to the outside of the coolant umbilical (1) with 3 or 4 tie-straps (MS
3367-2-0) (2).
2
1
3
Figure 2-16.
Securing Positive Lead to Outside of Coolant Umbilical.


Back to Top