MWO-5-2350-262-35-4

ARMORED COMBAT EARTHMOVER (ACE), M9

MODIFICATION WORK ORDER

  MWO-5-2350-262-35-4 - Page 28 of 207

MWO 5--2350--262--35--4
2--9
SECTION IV
INSTALLATION OF UMBILICAL CABLE DISCONNECT
BRACKET -- CONTINUED
WARNING
Serious hearing loss and eye injury can occur during drilling and grinding operations.
Wear ear and eye protection.
NOTE
Apply tape over area where holes will be drilled to make it easier to mark locations and
drill holes.
NOTE
Steps d through f below apply to Figure 2--6.
d.
Using right forward hole on suspension control levers mounting plate as a reference, as shown on
Figure 2--6, mark locations on vehicle forward left bulkhead for drilling two holes to mount HDC umbilical
cable disconnect bracket.
e.
Using a 90--degree angle head drill, drill and tap two mounting holes for HDC umbilical cable bracket
using 25/64” drill bit and 7/16” tap. Ensure all warnings are heeded during drilling.
f.
Install two inserts, MS51831--102, in tapped mounting holes.
Figure 2--6. HDC Umbilical Cable Disconnect Bracket Mounting Hole Locations


Back to Top