TM 9-2330-356-14
(4) Install two capscrews (25), lockwashers (24),
and nuts (23) to fasten fan shroud (22) to base frame.
(5) Fasten rear firewall sections (14 and 12) to
rear panel (6) with two screws (13) and nuts (5).
(6) Install pump assembly (para 5-19).
(7) Install fuel lines to fuel tank and engine
(para 4-73).
(8) Install muffler and exhaust pipe (para 4-77).
(9) Install air
cleaner and intake hose
(para 4-74).
(10) Install wiring harness and electrical leads
(para 4-16).
(11) Ensure that engine crankcase is filled to
proper level with correct oil (para 4-71).
(12) Install top panel (26) to panels (6 and 7).
Secure with ten capscrews (27), twenty washers (28), and
ten nuts (29).
(13) Install engine and pump module on
semitrailer (para 5-18).
(14) Install capscrews (9) and nuts (10) for the rear
cross brace.
5-21.
Filter/Separator (M969, M969A1, M970, and
M970A1) (Fig. 5-12)
a..
Removal.
(1) Close valve M on curbside of semitrailer.
(2) Open drain valve Non sump to remove fuel
and sediment from filter/separator. Also remove drain
plugs on bottom of filter/separator.
(3) Tag and disconnect four lines from filter
separator (fig. 5-12).
(4) Remove split couplings from inlet and outlet
lines at filter/separator.
(5) Position either lift truck forks or dolly jack
under filter/separator to take up weight. Use care not to
damage sump components. Remove four nuts and
washers from mounting straps. Remove mounting straps
and webbing. Remove filter/separator.
b.
Installation.
(1) Position filter/separator at center of two
mounting brackets with drain valve at bottom and service
port opening toward outboard side.
(2) Position webbing on mounting straps. Install
mounting straps with washers and nuts. Tighten nuts to
142-158 lb.-ft.
(3) Connect four lines for filter/separator as
tagged. Two lines for filter/separator gage are connected
to elbows at front and rear of filter/separator. Fuel line is
connected to elbow at top of filter/separator. Pilot line is
connected to control valve on sump.
(4) Install split couplings to connect
filter/separator inlet and outlet to tank piping (para 4-85).
Tighten two bolts on split couplings to 95-105 lb.-ft.
(5) Close drain valve N and open valve M.
Figure 5-12. Filter/Separator Installation (M969, M969A1, M970, and M970A1).
5-26