TM-9-2330-356-14

SEMITRAILER, TANK: 5000 GALLON, BULK HAUL, SELF LOAD/UNLOAD M967 AND M967A1; SEMITRAILER, TANK: 5000 GALLON, FUEL DISPENSING, AUTOMOTIVE M969 AND M969A1; SEMITRAILER, TANK: 5000 GALLON, FUEL DISPENSING, UNDER/OVERWING AIRCRAFT M970 AND M970A1

TECHNICAL MANUAL; OPERATOR’S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL

OCTOBER 1990

  TM-9-2330-356-14 - Page 341 of 528

TM 9-2330-356-14
(4) Remove four mounting capscrews, washers,
and nuts from base of hose reel. Use a suitable lifting
device and remove hose reel from reel stand.
b.
Installation.
(1) Position hose reel on reel stand. Loosely
install four mounting screws, washers, and nuts. Do not
tighten until valve R is in place.
(2) Connect air lines to hose reel (para 4-89).
(3) Install valve R (fig 5-14) and meter assembly
(para 5-27).
(4) Tighten mounting nuts to 25-35 lb.-ft.
Figure 5-19. Deadman Hose Reel (M970 and M970A1).
5-33/(5-34 Blank)