TM-9-2330-356-14

SEMITRAILER, TANK: 5000 GALLON, BULK HAUL, SELF LOAD/UNLOAD M967 AND M967A1; SEMITRAILER, TANK: 5000 GALLON, FUEL DISPENSING, AUTOMOTIVE M969 AND M969A1; SEMITRAILER, TANK: 5000 GALLON, FUEL DISPENSING, UNDER/OVERWING AIRCRAFT M970 AND M970A1

TECHNICAL MANUAL; OPERATOR’S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL

OCTOBER 1990

  TM-9-2330-356-14 - Page 353 of 528

TM 9-2330-356-14
(8) Slide washer (8) up against bushing inside
upper leg, and install roll pin (2).
(9) Coat grease (item 17, Appendix E) heavily on
pinion and bevel gear teeth.
(10) Apply a continuous
1/8-inch diameter bead of
adhesive to inside of cover (1). Install cover (1) to upper
leg (5).
e.
In.stallation.
Install landing gear leg (para 4-54).
6-18. Emergency Valve Control Cables (Fig. 6-10)
a.
Removal.
(1) Remove
nut (3) and loosen
u-bolt
connections (9) securing cable(s) 10 valve operator A.
Remove cables.
(2) Loosen U-bolt connection securing cable to
emergency valve.
(3) Loosen U-bolt securing control cable to
emergency valve shut-off on curbside of trailer and
remove cable.
(4) On M970, M970A1 only, loosen the U-bolt
connection securing cable to cabinet door shut-off lever.
Remove cable.
(5) Pull cables through cable guides and remove
cables.
b.
Installation.
(1) Slide nut (3) over one end of the 120-inch
cable. Insert end of cable into end of adjusting bolt (4) and
tighten nut onto adjusting bolt.
(2) Thread cable through cable guide on cabinet
and U-bolt connection on emergency valve.
(3) Adjust cable (para 4-51).
(4) Connect the 168-inch cable to U-bolt
connection on valve operator A.
(5) Thread cable through cable guides and
connect to emergency valve shut-off.
(6) Adjust cable (para 4-51).
Figure 6-10. Emergency Valve Control and Cables.
6-11


Back to Top