TM 9-2815-205-34
3-11. AIR BOX HEATER HARDWARE REPLACEMENT (MODEL 5063-5392) (Cont)
b. Cleaning/Inspection
•
Ž
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles
and gloves and use in a well-ventilated area. Avoid contact with skin, eyes, and
clothes. Do not breathe vapors. Do not use near open frame or excessive heat.
The flash point is 100-138°F (38-50°C). If you become dizzy while using cleaning
solvent, get fresh air immediately and seek medical aid. If contact with eyes is
made, wash with water and get medical aid immediately.
Compressed air used for cleaning purposes will not exceed 30 PSI. Use only
with effective chip guarding and personal protective equipment (goggles/shield,
gloves, etc.)
(1) Clean solenoid valve with rag moistened with cleaning solvent. Clean brackets with cleaning
solvent. Dry components with compressed air.
(2) Inspect hoses for cuts, tears, kinks, or damage.
(3) inspect wiring harness for cuts, tears, burns, or damage.
c. Test
(1) Apply a 24 V dc power supply to the
solenoid valve (8) several times and listen
for the solenoid valve to “click” to
determine if it functions. If there is no
indication of valve movement, replace
unit.
(2) Disconnect power supply from solenoid
valve (8).
3-36
WARNING