TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 521 of 783

TM 9-2350-260-20-1-3
UNIVERSAL JOINT REPLACEMENT (Sheet 4 of 7)
18. Using hammer, tap final drive flange (Q) loose from
universal joint (L).
19. Remove final drive flange (Q) from universal joint
(L).
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable.
To prevent personal injury,
wear protective goggles and gloves and use only in a well-ventilated area.
Avoid
contact with skin, eyes, and clothes and don't breathe vapors.
Do not use near
open flame or excessive heat.
The flash point for Type #1 Dry Cleaning Solvent is
100 F (38 C) and for Type #2 is 138 ° F (50 C).
If you become dizzy while using
cleaning solvent, get fresh air immediately and get medical aid.
If contact with
eyes is made, wash your eyes with water and get medical aid immediately.
20. Wearing rubber gloves (Item 74, Appendix D) and
using rags (Item 65, Appendix D) and dry cleaning
solvent (Item 54, Appendix D), clean final drive
flange (Q).
21. Check final drive flange (Q) for cracks and breaks.
Replace if necessary.
INSPECTION:
1.
Using brush (Item 70, Appendix D) and solvent (Item 54, Appendix D) clean quick-disconnect clamp (A).
Be sure
tapped hole (B) is free of grease and dirt.
2.
Inspect tapped hole (B) for cross-threaded or stripped threads.
If threads are damaged, replace quick-disconnect
clamp (A).
3.
Check for looseness of pin (C).
If pin (C) is loose, replace quick-disconnect clamp (A).
Go on to Sheet 4.1
12-14
Change 2


Back to Top