TM 9-2815-205-34
3-24. AIR INLET HOUSING REPLACEMENT (MODEL 5063-5299)
This task covers: a. Removal
b. Cleaning/Inspection
c. Installation
INITIAL SETUP
MODELS
EXPENDABLE/DURABLE SUPPLIES
5063-5299
Cleaning solvent (App C, Item 9)
TOOLS AND SPECIAL TOOLS
EQUIPMENT CONDITION
Tool kit, general mechanics (App B, Item 107)
Para
Wrench, torque (App B, Item 116)
3-10
MATERIALS/PARTS
3-16
Screen, air inlet (App F, Item 149)
Gasket (App F, Item
55)
Description
Air box heater air line disconnected from
air inlet elbow
Fuel line clip removed
Lockwashers (App F, Item 99)
a. Removal
(1)
(2)
Scribe lines between air inlet adapter (1), air inlet housing (2), and blower (3) to assure
assembly in same location.
Remove four screws (4), four Iockwashers (5), four flat washers (6), air inlet adapter (1), and
gasket (7) from air inlet housing (2). Discard Iockwashers and gasket.
NOT E
One air inlet housing to blower screw was removed during removal of fuel line clip.
One air inlet housing to blower screw is located inside inlet housing.
(3) Remove two long screws (8), short screw (9), two mid-sized screws (10), five Iockwashers (11),
five flat washers (12), air inlet housing (2), and screen (13) from blower (3). Discard screen and
Iockwashers.
b. Cleaning/Inspection
Dry cleaning solvent P-D-680 Is toxic and flammable. Wear protective goggles
and gloves and use in a well-ventilated area. Avoid contact with skin, e s, and
clothes. Do not breathe vapors. Do not use near open flame or excessive heat.
The flash point Is 100-138 Degrees F (38-50 Degrees C). If you become dizzy
while using cleaning solvent, get fresh air immediately and seek medical aid. If
contact with eyes is made, wash with water and get medical aid immediately.
Compressed air used for cleaning purposes will not exceed 30 PSI. Use only
with effective chip guarding and personal protective equipment (goggles/
shield, gloves, etc.)
3-80