TM-9-2815-205-34

ENGINE WITH CONTAINER; MODELS 5063-5299, 5063-5392, 5063-5393, 5063-5395, 5063-5398, 5063-539F, 5063-539L

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE

AUGUST 1992

  TM-9-2815-205-34 - Page 215 of 596

TM 9-2815-205-34
3-27. AIR INLET HOUSING REPLACEMENT (MODELS 5063-5395, 5063-5398, AND 5063-539F)
This task covers: a. Removal
b. Cleaning
c. Installation
INITIAL SETUP
MODELS
EXPENDABLE/DURABLE SUPPLIES
5063-5395 5063-5398 5063-539F
Cleaning solvent (App C, Item 9)
TOOLS AND SPECIAL TOOLS
EQUIPMENT CONDITION
Tool kit, general mechanics (App B, Item 107)
Para Description
Wrench, torque (App B, Item 116)
3-3 Turbocharger removed
3-19 Fuel line clip removed
MATERIALS/PARTS
1
Screen, air inlet (App F, Item 149)
5
Lockwashers (App F, Item 99)
a. Removal
NOT E
Right middle air inlet housing screw was removed during removal of fuel line clip.
(1) Remove two long screws (1), three short screws (2), five Iockwashers (3), five flat washers (4),
air inlet housing (5), and screen (6) from blower (7). Discard screen and Iockwashers.
(2) If necessary, remove plug (8) from air inlet housing (5).
b. Cleaning
Ž
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles
and gloves and use in a well-ventilated area. Avoid contact with skin, eyes, and
clothes. Do not breathe vapors. Do not use near open flame or excessive heat.
The flash point is 100-138 Degrees F (38-50 Degrees C). If you become dizzy
while using cleaning solvent, get fresh air immediately and seek medical aid. If
contact with eyes is made, wash with water and get medical aid immediately.
• Compressed air used for cleaning purposes will not exceed 30 PSI. Use only
with effective chip guarding and personal protective equipment (goggles/shield,
gloves, etc.)
Clean air inlet housing with fuel oil and dry with compressed air.
3-86
WARNING


Back to Top