TM 9-2815-205-34
3-34. OIL PUMP INLET TUBE REPLACEMENT (MODEL 5063-5299)
This task covers: a. Removal
b. Cleaning/Inspection
c. Installation
INITIAL SETUP
MODELS
5063-5299
TOOLS AND SPECIAL TOOLS
Tool kit, general mechanics (App B, Item 107)
Wrench, torque (App B, Item 116)
MATERIALS/PARTS
Gasket (App F, Item 54)
Lockwashers (App F, Item 98
Lockwashers (App F, Item 99
MATERIALS/PARTS (Cent)
2
Bolt, self-locking (App F, Item 192)
2
Nuts, self-locking (App F, Item 109)
EXPENDABLE/DURABLE SUPPLIES
Cleaning solvent (App C, Item 9)
EQUIPMENT CONDITION
Para Description
3-33 Oil pan removed
a. Removal
(1)
(2)
(3)
(4)
(5)
(6)
Remove two bolts (1) and two Iockwashers (2) fastening oil pump inlet tube (3) to bottom of
lower front cover (4). Discard Iockwashers.
Remove two screw (5), two lockwashers (6), and two special washers (7) fastening support
bracket (8) to main bearing cap (9). Discard lockwashers.
Remove oil pump inlet tube (3) and gasket (10) from cylinder block. Discard gasket.
Remove two self-locking bolts (11), two flat washers (12), and strainer (13) from inlet
Discard self-locking bolts.
tube (3).
Remove two screws (14), two Iockwashers (15), two special washers (16), and bracket (17)
from inlet tube (3). Discard Iockwashers.
Remove two self-locking nuts (18), eight flat washers (19), two screws (20), and bracket (8)
b.
from bracket (17). Discard nuts.
-
Cleaning/Inspection
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles
and gloves and use in a well-ventilated area. Avoid contact with skin, eyes, and
clothes. Do not breathe vapors. Do not use near open flame or excessive
heat.
The flash point Is 100-138 Degrees F (38-50 Degrees C). If you become dizzy
while using cleaning solvent, get fresh air Immediately and seek medical aid. If
contact with eyes is made, wash with water and get medical aid immediately.
Compressed air used for cleaning purposes will not exceed 30 PSI. Use only
with effective chip guarding and personal protective equipment (goggles/shield,
gloves, etc.)
(1) Wash components with cleaning solvent and dry with compressed air.
(2) Inspect tubes, brackets, and strainer for cracks or damage.
3-106