TM 9-2815-210-34-2-2
c .
Cleaning.
FRAME 1
1.
2.
3.
4.
WARNING
Do not use dip tank (2) unless you are experienced at
it .
Chemicals in dip tank can cause serious burns to
personnel.
Using crane, lower crankcase (1) into dip tank (2). Clean crankcase in
dip tank.
Lift crankcase (1) out of dip tank (2).
Mount crankcase (1) on maintenance stand. Refer to para 3-31.
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame.
Keep a fire extinguisher nearby when sol-
vent is used.
Use only in well-ventilated places. Fail-
ure to do this may result in injury to personnel and
damage to equipment.
Eye shields must be worn when using compressed air.
Eye injury can occur if eye shields are not used.
Using fuel passage cleaning brush, clean oil passages in crankcase (1).
Flush passages with dry cleaning solvent.
Blow passages dry with compressed
air.
GO TO FRAME 2
4-10